LSP100K
Battery Input Data
Battery Types Li-Ion or Lead-acid
Nominal Battery Voltage (V) 48
Max. Charging Voltage (V) SSO (Configurable)
Max. Charging Current (A) 70
Max. Discharging Current (A) 70
Battery Capacity (kWh) >3
Charging Mode for Li-Ion Battery Self-adaption to BMS
Charging Mode for Lead-acid Battery 3-stage
AC Output Data(On-grid)
Max.Apparent Power Output to Utility Grid (VA) 3600
Max.Apparent Power from Utility Grid (VA) 6000
Nominal Output Voltage (V) 230
Nominal Ouput Frequency (Hz) 50/60
Max.AC Current Output to Utility Grid (A} 16
Max.AC Current From Utilily Grid(A} 26
Output Power Factor -1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDI <3%
Grid Connection Single phase
Inrush Current 10A/10us
Max. Output Fault Current 50A/20us
AC Output Data(Back-up)
Max. Output Apparent Power (VA) 3600
Peak Output Apparent Power (VA) 4700,30sec
Automatic Switch Time <0.01s
Nominal Output Voltage (V) 230 (±2%)
Nominal Output Frequency (Hz} 50/60 (±0.2%)
Max. Output Current (A) 16
Back-up Over Current Protection(A} 40
Output THDV (linear load} <3%
Protection
Anti-islanding Protection lntegrated(AFD)
Output Over Current Protection Integrated
Output Short Protection Integrated
Output Over Voltage Protection Integrated
General Data
Operation Temperature Range ('C) -25-60
Storage Temperature ("C) -40-65
Relative Humidity 0-95%
Operation Altitude (m) 4000
Cooling Natural Convection
Noise (dB) <25
User Interface LCD &APP
Interface With BMS RS 485 /CAN
Communication With Cloud Wi-Fi
Weight (kg) 15.6
Size (Width•Height•Depth mm) 550•320·110
Mounting Wall Bracket
Protection Degree IP 65
Environment Category Outdoor & indoor
Standby Self Consumption (W) <10
Topology High Frequency Isolation
Certifications & Standards
Safety Regulation & EMC G83,CE, EN61000-6-1/3, EN62109-6-1/2, AS4777, IEC62040-1
Key Features
Infinity Innovations Ltd
Shed 7, Bocking Farm,
Cross Roads,
Keighley
BD22 9BG
01274 833115