All our Lux Power Controllers come with 10 Years manufacturer’s warranty, However at an extra cost you can upgrade your warranty to 20 years giving you a piece of mind when it come to your investment
Most controllers on the market only allow you a maximum of 60 amps charge & Discharge rate. You will also need to use a minimum of 3 Lithium batteries to achieve the maximum charge and discharge rate of 3Kw. Our Lux Power LXP 3600 AC Controller allows you to us up to 70 amps and with just 2 of our Aobo Uhome 2400 or GreenLinx lithium batteries we can achieve up to 3.5Kw and a maximum of 3.6Kw with 3 or more batteries.
Our Lux Power LXP 3600 AC comes we Free Advanced Monitoring that gives you a full insight to your system showing more information than you can handle. This information can be viewed via a web portal or Mobile App.
The Lux Power range now comes with advanced weather compensation (Weather predictions). This incredible feature allows you the customer to program your night time grid charging of your Lux power controller and batteries base on tomorrow's irradiance (Weather) in your local area. This feature is designed for you to controller and operate your battery system at its optimum level, saving you more money on your investment. "There is no need to fill your batteries from the grid in the night at a cost if tomorrow’s weather is going to be sunny and you can fill your batteries for free!"
LXP3600 AC
Battery Input Data
Battery Types Li-Ion or Lead-acid
Nominal Battery Voltage (V) 48
Max. Charging Voltage (V) SSO (Configurable)
Max. Charging Current (A) 70
Max. Discharging Current (A) 70
Battery Capacity (kWh) >3
Charging Mode for Li-Ion Battery Self-adaption to BMS
Charging Mode for Lead-acid Battery 3-stage
AC Output Data(On-grid)
Max.Apparent Power Output to Utility Grid (VA) 3600
Max.Apparent Power from Utility Grid (VA) 6000
Nominal Output Voltage (V) 230
Nominal Ouput Frequency (Hz) 50/60
Max.AC Current Output to Utility Grid (A} 16
Max.AC Current From Utilily Grid(A} 26
Output Power Factor -1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDI <3%
Grid Connection Single phase
Inrush Current 10A/10us
Max. Output Fault Current 50A/20us
AC Output Data(Back-up)
Max. Output Apparent Power (VA) 3600
Peak Output Apparent Power (VA) 4700,30sec
Automatic Switch Time <0.01s
Nominal Output Voltage (V) 230 (±2%)
Nominal Output Frequency (Hz} 50/60 (±0.2%)
Max. Output Current (A) 16
Back-up Over Current Protection(A} 40
Output THDV (linear load} <3%
Protection
Anti-islanding Protection lntegrated(AFD)
Output Over Current Protection Integrated
Output Short Protection Integrated
Output Over Voltage Protection Integrated
General Data
Operation Temperature Range ('C) -25-60
Storage Temperature ("C) -40-65
Relative Humidity 0-95%
Operation Altitude (m) 4000
Cooling Natural Convection
Noise (dB) <25
User Interface LCD &APP
Interface With BMS RS 485 /CAN
Communication With Cloud Wi-Fi
Weight (kg) 15.6
Size (Width•Height•Depth mm) 550•320·110
Mounting Wall Bracket
Protection Degree IP 65
Environment Category Outdoor & indoor
Standby Self Consumption (W) <10
Topology High Frequency Isolation
Certifications & Standards
Safety Regulation & EMC G83,CE, EN61000-6-1/3, EN62109-6-1/2, AS4777, IEC62040-1
Key Features
Under Self Use mode, AC coupled inverter will detect the power of on-grid inverter generated, which will be used by local loads first, and rest will be stored in the battery by using AC coupled inverter, excessive power will be feed back into the grid. This is the default mode which will increase the self consumption rate and reduce the energy bill significantly
Infinity Innovations Ltd
Shed 7, Bocking Farm,
Cross Roads,
Keighley
BD22 9BG
01274 833115
infinityinnovations.co.uk